It is normally used as a circulator and low limit cooling controller.

Honeywell L6006A1145 - High or Low Limit & Circulator, Horizontal Mount Aquastat, 100-240°F range, 5-30°F Adj Differential - Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. L6006A Aquastatfi Controller APPLICATION The Honeywell SUPER TRADELINEfi L6006A Controller operates in response to temperature changes in hydronic heating systems.

L6008A—makes the burner circuit on a drop in water temperature. Manufacturer's warranty still applies.

Here is a link to detailed for the HONEYWELL L6006A AQUASTAT Installation & Operating Instructions [PDF] Reader Comments & Q&A.

Also for: Aquastat l4006e, Aquastat l4006h, Aquastat l4006b. Honeywell L4006, L6006 Single and Multi-Function Aquastat Controllers. It provides spdt switching for high limit, low limit or circulator control.

Aquastat L4006A controller pdf manual download. L4008L—is used as a 2-stage Aquastat® controller.

But readers looking for specific aquastat control information should always first try the control manufacturer.The large dial whose numbers you see when the control cover is on is the HI or HIGH LIMIT - see SETPOINT INDICATING WHEELin Honeywell's illustration adapted at above leftOn the L6006A controller, where does the white neutral supplies go?Here is what the manufacturer says:

Therefore, our standard return policy does not apply to this item. M8806 SETPOINT INDICATING DIAL DIFFERENTIAL ADJUSTMENT WHEEL ADAPTER CLAMP SCREWS INSERTION ELEMENT It is attached downstream from a heat exchanger/air handler unit in my gas-fired hydronic heating system, and the fan is being controlled by the aquastat.We discuss relationship among HI, LO, DIFF, and heating burner cut-in, cut-out, and circulator lockout that are provided on the combination control. It has one large dial and one smaller (differential) dial. The L6006A is designed for horizontal or vertical insertion/mounting using an immersion well (not included). It provides spdt switching for high limit, low limit or circulator control. Single and Multi … When Installing this Product… We explain how to disable the LO control when a tankless coil is not in use on a boiler. We define the HI LO and DIFF controls on heating boiler aquastats and explains what they do and how they work. At this time, we do not carry this unit. After explaining the operation of an aquastat's Hi, Lo, and Diff controls we review the newer universal replacement aquastat from Honeywell, the L7224U Universal Aquastat, followed by a discussion of the simpler single-limit control switches.For proper selection of settings, follow the boiler manufacturer recommendations.I have the large dial at 160and the differential to 5 degrees.On 2020-06-05 - by (mod) - where do the wires go on the L6006A?On 2020-06-05 by Richard - On the L6006A controller, where does the white neutral supplies go?My aquastat is the Honeywell L6006A.

L6006A Aquastat® Controller INSTALLATION INSTRUCTIONS APPLICATION INSTALLATION The Honeywell SUPER TRADELINE® L6006A Controller operates in response to temperature changes in hydronic heating systems.

[Click to enlarge any image] Failure to comply with this could result in substantial property damage, severe personal injury or death.Do not use this item for any installation or repair of potable water applications. Please check the box below to confirm you are aware that this item is for non-potable water applications only.Feel free to send us a message and we will follow up ASAP. Honeywell L6006A Installation, Wiring & Operation Manual.